Hospital Isolation Panels

 

As you know, operation rooms, CCU, ICU, NICU, radiology, dialysis and laboratories are the most important sections in hospitals or treatment centers. Therefore, it is very important to consider designing electrical systems of the sectors. Until 1984, the required transformers and isolation panels for hospitals were purchased from the USA, England and other countries. This caused exiting considerable foreign currency from the country. Therefore, by considering the country’s need to self-sufficiency to produce the product, Tayf Asa Co produced isolation systems with 3.5, 5, 8, 10, 12.5, 20 and 25 KV. This company supplied the first set of the panels in 1984.

The produced isolation panels by the company have been tested by the Electronic Institute of Technical College, Tehran University. They are produced according to IEC National Standard (single-phase separator transformers) and Safety Isolating Transformer 353 Standard.

Since 2004, the company has produced its products according to VED 0100-710 and VDE 0107 Standards.

 

General Specifications:

 Using the galvanized or greasy sheets (or stainless steel sheets, if customer wants)

 Using furnace electrostatic powder painting line with 80-120 micron

 Different IP maintenance degrees (according to the customer demand)

 The proper hinged sweepers

 Using sheets with 1.5 mm thickness in wall panels

 Nominal voltage of 220V

 Double miniature circuit breakers with cutting power of 10 KV for the system inputs/outputs

 Ease to increase or reduce number of the system outputs

 The plastered phase, null and earth busbars by tin and copper (10*2) with minimum nominal current of 100A

 Standard rail terminals

 Fan with thermostat

 Power of 3.5, 5, 7.5, 15, 20 and 25 KVA

 Two years guarantee and 15 years after sale services

  

Special Specifications:

 Produced in accordance with IEC 61557-8 Standard

 Produced in accordance with IEC 60364-7-10 Standard

 Produced in accordance with VDE 0107 Standard

 Produced in accordance with VDE 0100-710 Standard

 Produced in accordance with Safety Isolating Transformator 353 Standard

 Tested by the Electronic Institute of Technical College, Tehran University

 Programmable earth fault relays with capability to connect network and BMS

 Transformer with electrostatic shield to prevent joints and decrease electromagnetic conflict with H isolation class

 Digital monitor to ensure the system operation with sound and visual alarm as well as leakage indicator

 

 Technical Specifications:

 


Hospital isolation panels’ size

Power (KW) Length (mm) Width (mm) Depth (mm) Weight (kg)
3.5 90 60 24 90
5 90 60 24 90
7.5 90 60 24 90
10 90 60 24 90
15 100 70 24 90
20 100 70 24 90
25 120 80 90 100

 

 The produced equipments of operation room by Tayf Asa Alborz Co.

 Digital clock and chronometer for operation room

  

Technical Specifications:

 Wall built-in type

 With one digital clock

 Three digital chronometers

 Rechargeable battery and back-up from 30 minutes to 4 hours

 Four-canal socket box

 

 Technical Specifications:

 Stainless steel

 Four locked and waterproof sockets

 One or four earth plugs

 Four-canal socket box, Legrand Mark

 

 Stainless steel

 Four locked Legrand sockets

 One or four earth plugs

 Rotating four-canal locked socket

 

 Stainless steel

 Four locked Legrand sockets

 One or four earth plugs