Hospital Isolation Panels
As you know, operation rooms, CCU, ICU, NICU, radiology, dialysis and laboratories are the most important sections in hospitals or treatment centers. Therefore, it is very important to consider designing electrical systems of the sectors. Until 1984, the required transformers and isolation panels for hospitals were purchased from the USA, England and other countries. This caused exiting considerable foreign currency from the country. Therefore, by considering the country’s need to self-sufficiency to produce the product, Tayf Asa Co produced isolation systems with 3.5, 5, 8, 10, 12.5, 20 and 25 KV. This company supplied the first set of the panels in 1984.
The produced isolation panels by the company have been tested by the Electronic Institute of Technical College, Tehran University. They are produced according to IEC National Standard (single-phase separator transformers) and Safety Isolating Transformer 353 Standard.
Since 2004, the company has produced its products according to VED 0100-710 and VDE 0107 Standards.
General Specifications:
Using the galvanized or greasy sheets (or stainless steel sheets, if customer wants)
Using furnace electrostatic powder painting line with 80-120 micron
Different IP maintenance degrees (according to the customer demand)
The proper hinged sweepers
Using sheets with 1.5 mm thickness in wall panels
Nominal voltage of 220V
Double miniature circuit breakers with cutting power of 10 KV for the system inputs/outputs
Ease to increase or reduce number of the system outputs
The plastered phase, null and earth busbars by tin and copper (10*2) with minimum nominal current of 100A
Standard rail terminals
Fan with thermostat
Power of 3.5, 5, 7.5, 15, 20 and 25 KVA
Two years guarantee and 15 years after sale services
Special Specifications:
Produced in accordance with IEC 61557-8 Standard
Produced in accordance with IEC 60364-7-10 Standard
Produced in accordance with VDE 0107 Standard
Produced in accordance with VDE 0100-710 Standard
Produced in accordance with Safety Isolating Transformator 353 Standard
Tested by the Electronic Institute of Technical College, Tehran University
Programmable earth fault relays with capability to connect network and BMS
Transformer with electrostatic shield to prevent joints and decrease electromagnetic conflict with H isolation class
Digital monitor to ensure the system operation with sound and visual alarm as well as leakage indicator
Technical Specifications:
Hospital isolation panels’ size |
||||
Power (KW) | Length (mm) | Width (mm) | Depth (mm) | Weight (kg) |
3.5 | 90 | 60 | 24 | 90 |
5 | 90 | 60 | 24 | 90 |
7.5 | 90 | 60 | 24 | 90 |
10 | 90 | 60 | 24 | 90 |
15 | 100 | 70 | 24 | 90 |
20 | 100 | 70 | 24 | 90 |
25 | 120 | 80 | 90 | 100 |
The produced equipments of operation room by Tayf Asa Alborz Co.
Digital clock and chronometer for operation room
Technical Specifications:
Wall built-in type
With one digital clock
Three digital chronometers
Rechargeable battery and back-up from 30 minutes to 4 hours
Four-canal socket box
Technical Specifications:
Stainless steel
Four locked and waterproof sockets
One or four earth plugs
Four-canal socket box, Legrand Mark
Stainless steel
Four locked Legrand sockets
One or four earth plugs
Rotating four-canal locked socket
Stainless steel
Four locked Legrand sockets
One or four earth plugs
![]() |
![]() |
![]() |